STS Smart Energy Meters

GSD7666- DG2 Single-phase DIN-rail Prepayment Energy Meter

GSD7666- DG2 is an advanced & compact DIN-rail energy meter with split-type structure & Class 1 accuracy.Complying with STS standard, the meter is suitable for commercial & residential cus

Details

GSD7666- DG2 is an advanced & compact DIN-rail energy meter with split-type structure & Class 1 accuracy.Complying with STS standard, the meter is suitable for commercial & residential customers and has outstanding tamper detection features. It could make communication with the external Customer Interface Unit(CIU) by M-bus, PLC or RF, and its installation requirements are also optional.

Main Features
·Dual-relay
·Multi-tariff
·DLMS/COSEM compliant
·STS prepayment
·20-digit STS encryption
·35mm DIN-rail installation
·Tamper detection & recording
·MCU linking to CIU by M-bus/PLC/RF(optional)
·Slim-line & space-saving design
·Disconnecting on overload & no-credit condition
·Programmable warning of power limit & low credit
·With Infrared port/RS485/virtual token carrier (optional)
·Surge protection against lightening & other line surges

Split-type Structure for Anti-tampering Protection

 

The meter consists of two parts, the MCU (Metering & Control Unit) and CIU (Customer Interface Unit),which could be linked via communication modes of M-bus, PLC or RF based on requirements.
The CIU is installed inside the customer’s home for inputting prepayment token and searching for information, while the MCU is normally installed in a meter enclosure away from the customer’s home.

GSD7666- DG2 Single-phase DIN-rail Prepayment Energy Meter

ELECTRICAL PARAMETERS

VOLTAGE
Nominal voltage Un 230V
Limited voltage  70% ~ 120%Un
FREQUENCY
Nominal frequency fn  50 ~ 60Hz
Tolerance ±5%
CURRENT
Basic current(Ib) 5A
Maximum current(Imax) 60A/80A
Starting current(Ist) 20mA
Active energy constant 1000imp/kWh
MEASUREMENTACCURACY
Active energy as IEC62053-21 Class 1.0
POWERCONSUMPTION
Voltage circuit <2W<8VA
Current circuit <1VA
TEMPERATURE RANGE
Operation range -25℃ ~ +70℃
Storage range -40℃ ~ +85℃

INSULATION

Insulation level 4kV rms 1min
Impulse withstand voltage 8kV 1.2/50 μs
Insulation system classification Protection class II

ELECTRO MAGNETIC COMPATIBILITY

ELECTROSTATIC DISCHARGES
Contact discharge 8kV
Air discharge 15kV
ELECTROMAGNETIC RF FIELDS
27MHz to 500MHz typical 10V/m
100kHz to 1GHz typical 30V/m
Fast transient burst test 4kV
MECHANICAL REQUIREMENTS
Meter case protection class IP54
Insulation system classification Protection class II
Maximum cable size 8 mm

GSD7666- DG2 Single-phase DIN-rail Prepayment Energy Meter

Feedback