GSD7666-WJ3 is an advanced single-phase multi-function smart meter used to measure energy accurately for commercial & residential customers, with a wide range of functions, smart measurement &
GSD7666-WJ3 is an advanced single-phase multi-function smart meter used to measure energy accurately for commercial & residential customers, with a wide range of functions, smart measurement & flexible communication modules for remote reading & management.
It could be used for either prepayment (compliant with STS standard) or postpayment applications (optional),with outstanding anti-tamper functions like detection of terminal cover opening to help utilities in revenueprotection.It could communicate with CIU or DCU (Data Concentrator Unit for AMR/AMI System) by different communication modes like PLC/GPRS/3G/4G/RF based on requirements.
Main Features
·Dual-relay ·Multi-tariff ·DLMS/COESM compliant ·Infrared port/RS485 ·Tamper detection & recording ·LCDdisplay capable of reading without power ·Protection cover for infrared port(optional) |
·Active/reactive energy measurement ·Double CT for phase & neutralline ·Disconnecting on overload & no-creditcondition ·Prepayment/postpayment mode switchable ·Display scroll button or STS keypad (optional) ·Programmable warning of load limit & low credit |
Split-type Structure for Anti-tampering Protection
The CIU(Customer Interface Unit) is optional, linking to the MCU(Metering & Control Unit) with communication modes of M-bus, PLC or RF based on requirements.
The CIU is installed inside the customer’s home for inputting prepayment token and searching for information, while the MCU is normally installed in a meter enclosure away from the customer’s home.
ELECTRICAL PARAMETERS
VOLTAGE | |
Nominal voltage Un | 230V |
Limited voltage | 70% ~ 120%Un |
FREQUENCY | |
Nominal frequency fn | 50 ~ 60Hz |
Tolerance | ±5% |
CURRENT | |
Basic current(Ib) | 5A |
Maximum current(Imax) | 60A (80A/100A optional) |
Starting current(Ist) | 20mA |
Active energy constant | 1000imp/kWh |
MEASUREMENTACCURACY | |
Active energy as IEC62053-21 | Class 1.0 |
POWERCONSUMPTION | |
Voltage circuit | <2W<8VA |
Current circuit | <1VA |
TEMPERATURE RANGE | |
Operation range | -25℃ ~ +70℃ |
Storage range | -40℃ ~ +85℃ |
INSULATION
Insulation level | 4kV rms 1min |
Impulse withstand voltage | 8kV 1.2/50 μs |
Insulation system classification | Protection class II |
ELECTRO MAGNETIC COMPATIBILITY
ELECTROSTATIC DISCHARGES | |
Contact discharge | 8kV |
Air discharge | 15kV |
ELECTROMAGNETIC RF FIELDS | |
27MHz to 500MHz typical | 10V/m |
100kHz to 1GHz typical | 30V/m |
Fast transient burst test | 4kV |
MECHANICAL REQUIREMENTS | |
Meter case protection class | IP54 |
Insulation system classification | Protection class II |
Maximum cable size | 8 mm |